VERTIV-GXT-3000MTPLUSC230

UPS VERTIV LIEBERT GXT-MTPLUS CX – ON-LINE 3000VA/2700W STANDARD BACKUP MODEL

175,000

Compare
Categories: , ,

 

Input
Capacity 3000 VA / 2400 W
Voltage Range Low Line Transfer
85VAC/75VAC/65VAC/55VAC±5% or 160VAC/140VAC/120VAC/110VAC±5%
(Ambient Temp.<35°C)
( based on load percentage 100%–80% / 80%–70% / 70–60% / 60%–0)
Low Line Comeback
95VAC/85VAC/75VAC/65VAC or 175VAC/155VAC/135VAC/125VAC ± 5%
(Ambient Temp.<35°C)
( based on load percentage 100%–80% / 80%–70% / 70–60% / 60%–0)
High Line Transfer          145 VAC ± 5% or 300 VAC ± 5%
High Line Comeback 140 VAC ± 5% or 290 VAC ± 5%
Frequency Range 40Hz ~ 70 Hz
Phase Single phase with ground
Power Factor ≥0.99 @ nominal voltage (input voltage)
Output Capacity 
Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC
AC Voltage Regulation ±1% (Batt. Mode)
Frequency Range 47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
Frequency Range (Battery Mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
Current Crest Ratio  3:1
Harmonic Distortion ≤ 3% THD (linear load); ≤6% THD (non-linear load)
Transfer Time AC Mode to Batt. Mode :                   Zero
Inverter to Bypass 4 ms (Typical)
Waveform (Battery Mode) Pure Sinewave
Efficiency
AC Mode 90%
Battery Mode 88%
Battery 
Battery Numbers 6
Charging Current 1.0A/2.0A/4.0A/6.0A (adjustable through the jumper settings on charger board)
Charging Voltage 82.1 VDC ± 1%

 

Input
Capacity 3000 VA / 2400 W
Voltage Range Low Line Transfer
85VAC/75VAC/65VAC/55VAC±5% or 160VAC/140VAC/120VAC/110VAC±5%
(Ambient Temp.<35°C)
( based on load percentage 100%–80% / 80%–70% / 70–60% / 60%–0)
Low Line Comeback
95VAC/85VAC/75VAC/65VAC or 175VAC/155VAC/135VAC/125VAC ± 5%
(Ambient Temp.<35°C)
( based on load percentage 100%–80% / 80%–70% / 70–60% / 60%–0)
High Line Transfer          145 VAC ± 5% or 300 VAC ± 5%
High Line Comeback 140 VAC ± 5% or 290 VAC ± 5%
Frequency Range 40Hz ~ 70 Hz
Phase Single phase with ground
Power Factor ≥0.99 @ nominal voltage (input voltage)
Output Capacity 
Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC
AC Voltage Regulation ±1% (Batt. Mode)
Frequency Range 47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
Frequency Range (Battery Mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
Current Crest Ratio  3:1
Harmonic Distortion ≤ 3% THD (linear load); ≤6% THD (non-linear load)
Transfer Time AC Mode to Batt. Mode :                   Zero
Inverter to Bypass 4 ms (Typical)
Waveform (Battery Mode) Pure Sinewave
Efficiency
AC Mode 90%
Battery Mode 88%
Battery 
Battery Numbers 6
Charging Current 1.0A/2.0A/4.0A/6.0A (adjustable through the jumper settings on charger board)
Charging Voltage 82.1 VDC ± 1%

Description

UPS VERTIV LIEBERT GXT-MTPLUS CX – ON-LINE 3000VA/2700W STANDARD BACKUP MODEL